How we validate

A wrong verdict on a customer report is the most expensive mistake a quality tool can make. So every analysis in Mensuro has to reproduce published reference results before it ships.

The rule: each analysis is checked against worked examples from the standards and textbooks quality engineers already trust (AIAG MSA 4th edition, Bosch Booklet No. 10, Montgomery's Introduction to Statistical Quality Control and the NIST/SEMATECH e-Handbook), to the precision those sources print. The checks run automatically on every change to the engine. Statistics come from proven libraries (SciPy and statsmodels); Mensuro adds only the domain formulas, and those are what the checks cover.

Below is the current result for each reference case, published value next to Mensuro's. Small differences are the source's rounding. Engine version 0.1.0, checked October 27, 2026.

AIAG MSA 4th edition Gage R&R example (appraisers A, B, C; 10 parts; 3 trials)

Source: AIAG Measurement Systems Analysis Reference Manual, 4th edition (2010), Gage R&R worked example. Values as transcribed in SPC for Excel, 'Three Methods to Analyze Gage R&R Studies', Tables 1, 2, 4 and 5.

MethodQuantityPublishedMensuroMatch
Average & RangeEV0.2020.20186✓
Average & RangeAV0.230.22967✓
Average & RangeGRR0.3060.30577✓
Average & RangePV1.1051.10460✓
Average & RangeTV1.1461.14613✓
Average & Range%EV17.6117.612✓
Average & Range%AV20.0420.038✓
Average & Range%GRR26.6826.678✓
Average & Range%PV96.3796.376✓
ANOVASS Part88.36288.3619✓
ANOVASS Operator3.1673.1673✓
ANOVASS Repeatability3.1183.1179✓
ANOVASS Total94.64794.6471✓
ANOVAvariance gage_rr0.09140.09143✓
ANOVAvariance repeatability0.040.03997✓
ANOVAvariance reproducibility0.05150.05146✓
ANOVAvariance part_to_part1.0861.08645✓
ANOVAvariance total1.1781.17788✓
ANOVA% contribution gage_rr7.767.762✓
ANOVA% contribution repeatability3.393.394✓
ANOVA% contribution reproducibility4.374.368✓
ANOVA% contribution part_to_part92.2492.238✓

Average & Range verdict: Conditionally acceptable (ndc 5)

ANOVA verdict: Conditionally acceptable (ndc 4); Part x operator interaction p = 0.974; not significant, so it was pooled into repeatability.

Hard-bake process flow width, x-bar and R charts and capability (Montgomery Example 6.1)

Source: Montgomery, D. C., Introduction to Statistical Quality Control, 6th ed. (Wiley, 2009), Example 6.1: Table 6.1 (Phase I, samples 1-25), Table 6.2 (Phase II, samples 26-45), pp. 232-237; capability on pp. 234 and 351.

QuantityPublishedMensuroMatch
x-double-bar1.50561.50561✓
R-bar0.325210.32521✓
x-bar UCL / LCL1.69325 / 1.317951.69326 / 1.31797✓
R UCL0.687490.68749✓
Phase II points above UCL43, 4543, 45✓
sigma within (R-bar/d2)0.13980.13981✓
Cp1.1921.1921✓
Fraction nonconforming0.000350.000353✓

Glass container bursting strength, overall capability (Montgomery Examples 8.1 and 8.2)

Source: Montgomery, D. C., Introduction to Statistical Quality Control, 6th ed. (Wiley, 2009), Example 8.1 and Table 8.1 (p. 348), Example 8.2 (p. 352).

QuantityPublishedMensuroMatch
Mean / s264.06 / 32.02264.060 / 32.018✓
Cpl (overall)0.670.6669✓
Fraction below LSL0.02280.02271✓

Type 1 gage study, outer diameter, two-sided tolerance (Bosch Booklet No. 10, Procedure 1)

Source: Robert Bosch GmbH, Quality Management in the Bosch Group, Booklet No. 10: Capability of Measurement and Test Processes, edition 11.2019, chapter 4.1 example printout (p. 11) and Appendix B manual form (p. 35).

QuantityPublishedMensuroMatch
Mean / s6.0009 / 0.000994886.00090 / 0.00099488✓
abs(bias)0.00110.001100✓
Cg (95% CI)2.01 (1.61 - 2.41)2.0103 (1.61 - 2.41)✓
Cgk (95% CI)1.64 (1.3 - 1.98)1.6417 (1.30 - 1.98)✓
%RE1.671.667✓
Tmin(Cg) / Tmin(Cgk)0.039701 / 0.0506960.039696 / 0.050696✓
Bias significantyesyes✓

Type 1 study with a one-sided limit and no natural limit, pull-off force (Bosch Booklet No. 10, Appendix B)

Source: Robert Bosch GmbH, Quality Management in the Bosch Group, Booklet No. 10: Capability of Measurement and Test Processes, edition 11.2019, Appendix B form 'Procedure 1 in case of a one-sided limit' (p. 42); formulas in chapter 4.1 (p. 9) and Appendix C.3 (pp. 44-45).

QuantityPublishedMensuroMatch
Mean / s80.524 / 0.418280.524 / 0.41824✓
LSL072.396872.39695✓

Gauge capability, one operator, 20 parts measured twice (Montgomery Example 8.7)

Source: Montgomery, D. C., Introduction to Statistical Quality Control, 6th ed. (Wiley, 2009), Example 8.7, Table 8.6 and Figure 8.14 (pp. 369-370).

QuantityPublishedMensuroMatch
x-double-bar / R-bar22.3 / 1.022.3000 / 1.0000✓
Average chart UCL / LCL24.2 / 20.4224.180 / 20.420✓
Range chart UCL3.2673.2670✓

Also checked

What this does and doesn't mean

Matching published examples shows the formulas, constants and decision rules are implemented correctly. It doesn't make a study valid on its own: the data still has to come from a sound study (the right parts, operators and readings), and your customer's own requirements apply where they differ. Every Mensuro result and report shows its receipt (method, constants, sample size and settings) so anyone can check how a number was made.